Input Types | Options 2

Miscellaneous Options

  • Activate Bell Output: When enabled the input type will activate the siren bell output programmed for the area.
  • Retrigger Bell Time: When enabled the input type will restart the bell timer on each subsequent alarm.
  • Save To Area Memory: When enabled the input type will save an alarm message to the area's alarm memory storage area.
  • Disarm Control Area On Input Restore: When enabled the input type will disarm the control area when an input assigned the input type restores from an alarm condition. Use this feature and the arming control area feature as an on and off key switch arming input.
  • Arm Control Area On Input Alarm: When enabled the input type will start arming the control area when an input assigned the input type generates an alarm condition.
  • Toggle Control Area On Input Alarm: When enabled the input type will toggle the state of the control area when the input assigned this input type generates an alarm.
  • Allow Force Arming Of Tampered Input: When enabled the input type will allow the input to be force armed if the input assigned the input type is tampered with.
  • Activate Entry Output on Bell Time: When enabled the input type will activate the entry output programmed for the area for the duration of the bell siren time. Use this feature for an input generating only a beeper alarm and assign the entry output a keypad beeper output. This option will not function if the bell option is enabled.

Output Activation Options

  • Activate Bypass Output: When enabled the input type will activate bypass output for the area if an input is bypassed.
  • Activate 24HR Tamper Output: When enabled the input type will activate the tamper output for the area if a tamper alarm occurs.
  • Activate Memory Output: When enabled the input type will activate the memory output for the area if an alarm occurs. This option can be used to indicate an alarm has occurred in the system. Use this feature to display an indication to the users of the system to prevent possible 'sitter' and 'hostage' situations.
  • Input Retriggers Output Time: When enabled the input type re-initiates the activation time of an output when the input is triggered. For example, reactivating lights when a motion sensor is triggered.
  • Activate Control Output On Alarm * : When enabled the input type will activate the control output when the input assigned generates an alarm.
  • Activate Control Output On Restore * : When enabled the input type will activate the control output when the input assigned restores from an alarm.
  • Deactivate Control Output On Alarm * : When enabled the input type will deactivate the control output when the input assigned generates an alarm.
  • Deactivate Control Output On Restore * : When enabled the input type will deactivate the control output when the input assigned restores from an alarm.
  • Toggle Control Output State On Alarm * : When enabled allows for toggling of output state.